Refrigerator product series
Model: DW-SW series
Type: Water-cooled heat dissipation (requires external cooling water source, generally refers to water tower cooling water)
Cooling capacity range: 100KW~2500KW
Temperature control accuracy: ±1℃~±2℃ (customizable high accuracy ±0.5℃)
Temperature range: 5℃~35℃ (low temperature water outlet 2℃ can be customized)
Customizable: Yes
Delivery time: 15 to 30 working days
Note: Due to limited space, if you want to know more product details, please contact our sales staff, we will provide solutions for different processes and equipment!
Introduction to water-cooled low-temperature freezer
This freezer is a refrigeration system consisting of three major components: a refrigeration system, a water system, and an electrical system. The core is the refrigeration system, which is composed of a compressor, an evaporator, a condenser, and an expansion valve. A water-cooled cryogenic freezer is a refrigeration device because its condenser (radiator) is a shell and tube type. It uses an external cooling tower and a cooling water pump to dissipate heat from the cooling tower. The core advantages of a water-cooled cryogenic freezer: high energy efficiency, used in places with cooling water sources, low noise, etc.
Application fields
With the development of modern science and technology, the requirements for diversified products are not met by normal temperature water for some processes and equipment. For example, pharmaceutical chemicals, food and beverages, special electronic materials and other high-end industries often require low-temperature freezers to meet process requirements. Dawoxi low-temperature freezers use foreign top-level brand compressors and advanced process structure design to meet some low-temperature freezing requirements within -40 degrees.
Freatures of refrigeration products
1. The temperature control system adopts a microcomputer controller with a simple and elegant interface, intuitive and easy operation, and various operating indication conditions are clear at a glance. The wide temperature range is -5℃~-40℃ and can be adjusted arbitrarily.
2. The core component compressor adopts internationally renowned brands such as Denmark DANFOSS, Germany BITZER, France Taikang, and the United States Copeland, which is the reliable guarantee for the operation of the unit.
3. The core refrigeration accessories are made from international brand components such as Danfoss from Denmark, Emersonguo from the United States and domestic top suppliers.
4. The pipe connection system can be configured according to customer requirements, using materials such as galvanized pipes, plastic pipes, and stainless steel.
5. Fluid equipment adopts well-known domestic brands, such as: Hangzhou Nanfang, Denmark Grundfos, Germany Wilo, Hangzhou Xinjie or imported brand water pumps or special customization according to process requirements.
6. The electrical appliances adopt internationally renowned electrical components such as LS Schneider Siemens Omron, etc., and no special machine room is required.
7. It has its own cooling system, cooling water pump, freezing water pump and water tank, which is easy to move and can be used immediately after it is turned on. It is suitable for areas with water shortage and mobile occasions.
8. The fully automatic intelligent control system controls water temperature, ultra-high temperature alarm, water flow, fault signal alarm output, and can be customized for remote control
9. It can meet the demand for process cooling source in 24-hour continuous and uninterrupted production in industrial production.
Note: The company provides on-site selection in the early stage to assist customers in choosing the appropriate model and process
Technical parameters of water-cooled low temperature freezer
model | DW-5LW | DW-6LW | DW-8LW | DW-10LW | DW-12LW | DW-15LW | DW-20LW | DW-25LW | DW-30LW | DW-40LW | ||
Cooling capacity | -10 | KW | 6.98 | 8.1 | 10.4 | 14.5 | 17.1 | twenty three | 28.3 | 32.7 | 45.6 | 56.2 |
-15 | 5.6 | 6.8 | 8.3 | 11.2 | 12.9 | 17.89 | 22.1 | 26.8 | 35 | 45 | ||
-20 | 4.4 | 5.3 | 6.4 | 9 | 10.7 | 13.5 | 18 | 21.3 | 27 | 36.5 | ||
power supply | Three-phase 380V 50Hz (60Hz) | |||||||||||
Total input power | KW | 2.95 | 4.75 | 5.55 | 6.75 | 8.9 | 10.6 | 13 | 17.2 | 26 | 34 | |
Temperature control range | ℃ | 5-35 | ||||||||||
Temperature control accuracy | ℃ | ±1 | ||||||||||
refrigerant | type | R22 (R407C/R410A/R404A) | ||||||||||
Control method | Thermal balance expansion valve | |||||||||||
compressor | form | Scroll type (piston type) | ||||||||||
power | (KW) | 2.2 | 4 | 4.8 | 6 | 7.8 | 9.5 | 11.5 | 15 | twenty two | 30 | |
Water tank | Water tank capacity | L | 30 | 30 | 30 | 60 | 60 | 60 | 100 | 150 | 240 | 300 |
Water tank material | SUS304 stainless steel | |||||||||||
Pipe diameter | G1〃 | G1〃 | G1〃 | G1〃 | G1-1/2" | G1-1/2" | G2〃 | G2-1/2" | G2-1/2" | G3〃 | ||
Water Pump | Yang Cheng | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
power | 0.75 | 0.75 | 0.75 | 0.75 | 1.1 | 1.1 | 1.5 | 2.2 | 4 | 4 | ||
Evaporator | type | Plate heat exchanger (shell and tube) | ||||||||||
Chilled water flow | m3/h | 1.36 | 2.26 | 2.72 | 3.37 | 4.57 | 5.44 | 6.95 | 9.14 | 14 | 18.3 | |
Condenser | type | Shell and tube | ||||||||||
Cooling water flow | m3/h | 2.58 | 3 | 4.1 | 5.4 | 6.84 | 9.8 | 12.3 | 16.8 | twenty two | 29 | |
Security protection | Compressor overheat protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, and antifreeze protection. | |||||||||||
Dimensions | long | mm | 890 | 890 | 1170 | 1170 | 1170 | 1700 | 1850 | 2000 | 2000 | 2200 |
Width | mm | 500 | 500 | 710 | 710 | 710 | 810 | 990 | 1130 | 1480 | 1660 | |
high | mm | 840 | 840 | 1200 | 1200 | 1200 | 1430 | 1680 | 1720 | 1800 | 1800 | |
Unit weight | KG | 150 | 168 | 260 | 300 | 450 | 530 | 750 | 835 | 1080 | 1125 |
Note: 1. The cooling capacity is measured under the following temperature conditions: the refrigerant is 60% glycol aqueous solution; the cooling water inlet/outlet temperature is 2/37℃. (The cooling capacity is the nominal cooling capacity)
2. Working range: Chilled water temperature range: 22℃ to 37℃, the cooling inlet temperature difference is 3.5℃ to 10℃; the refrigerant outlet temperature is 5℃ to 30℃, the refrigerant inlet and outlet temperature difference is 2.5℃ to 10℃.
3. The refrigerant is a 60% glycol aqueous solution prepared by the user (please refer to the low temperature refrigerant configuration table for details)
4. The above specifications and dimensions are subject to change without prior notice