• Air-cooled Low Temperature Freezer
Air-cooled Low Temperature Freezer
A low-temperature freezer is a refrigeration system consisting of three major components: a refrigeration system, a water system, and an electrical system. The core is the refrigeration system, which is composed of a compressor, an evaporator, a condenser, and an expansion valve. The air-cooled box-type chiller is a fin-type chiller that dissipates heat from the environment through one or more external rotor fans. The core advantages of air-cooled chillers: they come with a refrigeration system, a water pump, a water tank, and a control system. Customers can install them on site. They can be used in areas where water is scarce and cooling water is inconvenient...
  • Product Detail
  • Product Tags

Refrigerator product series

Model: DW-LA series
Type: air-cooled cooling
Refrigeration capacity range: 2.5KW~50KW
Temperature control accuracy: ±1℃
Temperature range: -5℃~-40℃
Water pump pressure: 2Kg~8kg (customized according to demand)
Can it be customized: Yes
Delivery time: 10~30 working days
Note: (Low-temperature freezer is a customized product, please confirm the listed parameters and pictures before ordering)


Introduction to air-cooled low-temperature freezer

1. Low-temperature freezer is a refrigeration system, water system, electrical system, the core of which is the refrigeration system, which is composed of compressor, evaporator, condenser, and expansion valve. The air-cooled box-type chiller is a chiller that dissipates heat from the environment through one or more external rotor fans because its condenser (radiator) is fin-type.
2. Core advantages of air-cooled chiller: It comes with a refrigeration system, water pump, water tank, and control system. Customers can install it by themselves when it arrives at the customer's site. It can be used in areas where water is scarce and cooling water is inconvenient.


Application fields

With the development of modern science and technology and the diversified requirements of products, some processes and equipment cannot be met by normal temperature water, such as pharmaceutical chemicals, food and beverages, special electronic materials, etc. These high-end industries often need low-temperature freezers to meet process requirements. Dawoxi low-temperature freezers use foreign top-level brand compressors and advanced process structure design to meet some low-temperature freezing requirements within -40 degrees.


Freatures of refrigeration products

1. The temperature control system adopts a microcomputer controller with a simple and generous interface, intuitive and easy operation, and all kinds of operating indication conditions are clear at a glance. A wide temperature range of -5℃ to -40℃ can be adjusted arbitrarily.
2. The core component compressor adopts internationally renowned brands such as Denmark DANFOSS, Germany Bitzer, France Taikang, and the United States Copeland, which is a reliable guarantee for the operation of the unit.
3 The core refrigeration accessories adopt international brand components such as Denmark Danfoss, the United States Emersonguo and domestic top suppliers.
4 The pipeline connection system can be configured according to the requirements of the customer, galvanized pipes, plastic pipes, stainless steel and other materials.
5 The fluid equipment adopts well-known domestic brands, such as: Hangzhou Nanfang, Denmark Grundfos, Germany Wilo, Hangzhou Xinjie, or imported brand water pumps or special customization according to process needs.
6 The electrical appliances adopt internationally renowned electrical components such as LS Schneider Siemens Omron, etc., and no special machine room is required.
7 It comes with a cooling system, cooling water pump, freezing water pump, and water tank, which is easy to move and can be used after turning on. Suitable for areas with scarce water resources and mobile occasions.
8. The fully automatic intelligent control system controls water temperature, high temperature alarm, water flow, fault signal alarm output, and can be customized for remote control
. 9. It can meet the needs of industrial production for 24-hour continuous uninterrupted production for process cooling sources.
Note: The company provides on-site selection in the early stage to assist customers in choosing the appropriate model and process flow planning.

Machine internal view

4-2011020TH1F0.jpg



Technical parameters of air-cooled low-temperature freezer

 (-30℃~-40℃ technical parameters, please consult sales representative)


modelDW-3LADW-5LADW-6LADW-8LADW-10LADW-12LADW-15LADW-20LADW-30LADW-40LA
Cooling capacity-10KW3.756.67.99.813.315.821.926.643.853.2
-1535.36.37.6610.812.617.0521.634.143.2
-202.324.25.168.6810.212.817.3625.634.72
power supplyThree-phase 380V 50Hz (60Hz)
Total input powerKW3.14.95.857910.81417.52735
Temperature control range5-35
Temperature control accuracy±1
refrigeranttype
R22 (R407C/R410A/R404A)
Control method
Thermal balance expansion valve
compressorformScroll type (piston type)
power(KW)2.244.867.89.511.515twenty two30
Water tankWater tank capacityL303030606060100150240300
Water tank material
SUS304 stainless steel
Pipe diameter
G1〃G1〃G1〃G1〃G1-1/2"G1-1/2"G2〃G2-1/2"G2-1/2"G3〃
Water PumpYang Cheng
20202020202020202020
power
0.750.750.750.751.11.11.52.244
Evaporatortype
Plate heat exchanger (shell and tube)
Chilled water flowm3/h1.362.262.723.374.575.446.959.141418.3
Condensertype
High efficiency copper tube sleeve aluminum foil fin type + external rotor fan
Cooling air volumem3/h30005000500010000100001500015000200003000030000
Security protectionCompressor overheat protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, and antifreeze protection.
Dimensionslongmm930114011401320168016801850200020002200
Widthmm520560560720810810990113014801660
highmm975104010401320143014301680172018001800
Unit weightKG13517521031045053075083510801125


Note: 1. The cooling capacity is measured under the following temperature conditions: the refrigerant is 60% glycol aqueous solution; the cooling water inlet/outlet temperature is 2/37℃. (The cooling capacity is the nominal cooling capacity)

          2. Working range: Chilled water temperature range: 22℃ to 37℃, the cooling inlet temperature difference is 3.5℃ to 10℃; the refrigerant outlet temperature is 5℃ to 30℃, the refrigerant inlet and outlet temperature difference is 2.5℃ to 10℃.

          3. The refrigerant is a 60% glycol aqueous solution prepared by the user (please refer to the low temperature refrigerant configuration table for details)

          4. The above specifications and dimensions are subject to change without prior notice



  1. <menu id="v094s"><dl id="v094s"></dl></menu>
  2. <bdo id="v094s"><dl id="v094s"></dl></bdo>
    1. 主站蜘蛛池模板: 福鼎市| 米易县| 临安市| 栾川县| 唐山市| 常州市| 如皋市| 浠水县| 安龙县| 阿坝| 额济纳旗| 富川| 麻江县| 绥中县| 鲜城| 大余县| 抚顺市| 连云港市| 武安市| 扎鲁特旗| 泾源县| 五台县| 班戈县| 延吉市| 嘉定区| 旬阳县| 清丰县| 滕州市| 隆回县| 彭州市| 南充市| 岳阳市| 曲沃县| 尉氏县| 南丰县| 弥勒县| 永定县| 常宁市| 荔波县| 财经| 克什克腾旗|